APAR status
Closed as program error.
Error description
The file sent from iSeries platform in EBCDIC format is not translated to ASCII after the file is received in IBM Sterling File Gateway, if the datatype and xlate parameters are not specified in C:D (PNODE) script.
Local fix
The work around is to mention Datatype=Text and xlate=yes in the C:D script on iseries.
Problem summary
Users Afected: All Problem Description: Files are not translated from EBCDIC to ASCII by default from CD iSeries to SI/CDSA after upgrading from V5.2.4 to V5.2.6.3_3. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. The Connect Direct protocol defines (2) values describing AS400 and iSeries platforms. The CDSA only recognized one these. The CDSA now recognizes both platforms during default copy parameter value processing restoring copy behavior when the COPY statement from the remote iSeries PNODE's process does not specify any destination SYSOPTS. Delivered In: 5020603_5
Temporary fix
Comments
APAR Information
APAR number
IT23473
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-12
Closed date
2018-02-23
Last modified date
2018-02-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: