Error description

  • The file sent from iSeries platform in EBCDIC format is not
    translated to ASCII after the file is received in IBM
    Sterling File Gateway, if the datatype and xlate parameters are
    not specified in C:D (PNODE) script.
    

Local fix

  • The work around is to mention Datatype=Text and xlate=yes in
    the C:D script on iseries.
    

Problem summary

  • Users Afected:
    All
    
    Problem Description:
    Files are not translated from EBCDIC to ASCII by default
    from CD iSeries to SI/CDSA after upgrading from V5.2.4 to
    V5.2.6.3_3.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    
    A code fix is provided.
    
    The Connect Direct protocol defines (2) values describing AS400
    and iSeries platforms.  The CDSA only recognized one these.  The
    CDSA now recognizes both platforms during default copy
    parameter value processing restoring copy behavior when the COPY
    statement from the remote iSeries PNODE's process does not
    specify any destination SYSOPTS.
    
    Delivered In:
    5020603_5
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT23473

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    526

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-12

  • Closed date

    2018-02-23

  • Last modified date

    2018-02-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
26 February 2018