APAR status
Closed as program error.
Error description
Execution Control Service Queue Assignment by parent BP is not considered by any INLINE executed sub BP. For example: If there's a Parent BP A and Child BP B where both BPs are defined to have the default queue 4. If you run BP A and with an Execution Control Service and change the queue from the default queue of 4 to queue 1, the Parent BP A will change and start running on queue 1. Then, if that Parent BP A inline invokes child BP B, the child BP steps will run on the default queue 4 and not inherit the current queue 1 from the parent BP A.
Local fix
RTC# 541112 FB/FB Circumvention: None
Problem summary
Users Affected: All Problem Description: Execution Control Service Queue assignment by parent BP is not considered by any INLINE executed sub BP. Platforms Affected: All
Problem conclusion
Resolution Summary: a code fix is provided. Delivered In: 5020603_3
Temporary fix
Comments
APAR Information
APAR number
IT23012
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-02
Closed date
2017-11-06
Last modified date
2017-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R526 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]