IBM Support

IT21537: MQRC 2035 RECEIVED BY MQOUTPUT NODE WHEN TRYING TO OPEN A QUEUE WHERE THE USER HAS LESS THAN SETALL PERMISSIONS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The MQOutput node always opens the output queue with
    MQOO_SET_ALL_CONTEXT despite the message context being set to
    more restrictive options such as PassAll. This can lead to an
    MQRC 2035 being returned from the MQOPEN call if the user
    running the Integration Node does not have setAll permissions
    on the output queue.
    
    The Integration Node should open the queue with appropriate
    MQOO options depending on the message context selected on the
    MQOutput node.
    
    Additional Symptom(s) Search Keyword(s):MQRC 2035,
    MQOO_SET_ALL_CONTEXT,  MQOutput node
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus V10 who use the MQOutput node
    with MQ security enabled.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The MQOutput node always opens the output queue with
    MQOO_SET_ALL_CONTEXT despite the message context being set to
    more restrictive options such as PassAll. This can lead to an
    MQRC 2035 being returned from the MQOPEN call if the user
    running the Integration Node does not have setAll permissions
    on the output queue.
    
    The Integration Node should open the queue with appropriate
    MQOO options depending on the message context selected on the
    MQOutput node.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT21537

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-21

  • Closed date

    2017-09-06

  • Last modified date

    2017-09-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]