APAR status
Closed as program error.
Error description
When running the mqsichangebluemixreporting command to configure an IIB instance for Bluemix Logmet reporting by providing Bluemix credentials, for example: mqsichangebluemixreporting {node} -g -l active -r us-south -o {org} -a {space} -u {user} -p {password} -d The command fails reporting BIP8075E "java.net.SocketException: Connection reset". Additional Symptom(s) Search Keyword(s):BIP8075E, mqsichangebluemixreporting, Bluemix Logmet
Local fix
The issue can be avoided by using the alternative steps to manually obtain the required Bluemix space and logging tokens and then using the mqsichangebluemixreporting command with the following options mqsichangebluemixreporting {node} -g -l active -x -i {spaceIdentifier} -t {loggingToken} As detailed in Knowledge Center topic: ?Configuring an integration server and loading the IBM Integration Bus Kibana dashboard manually? https://www.ibm.com/support/knowledgecenter/SSMKHH_10.0.0/com.ib m.etools.mft.doc/bz91188_.htm Note: The topic and command usage message BIP8372 incorrectly show a "-f" flag, please use correct syntax as show above with -x -i -t.
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus V10.0 who use Bluemix Logmet reporting. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: When running the mqsichangebluemixreporting command to configure an IBM Integration Bus instance for Bluemix Logmet reporting by providing Bluemix credentials, for example: mqsichangebluemixreporting {node} -g -l active -r us-south -o {org} -a {space} -u {user} -p {password} -d The command fails reporting BIP8075E "java.net.SocketException: Connection reset".
Problem conclusion
The mqsichangebluemixreporting command has been corrected to go directly to the required SSL protocol when connecting to Bluemix to acquire Logmet logging tokens. The command usage message BIP8372 and Knowledge Center topic bz91188_ will also be updated to show the required flags when using the alternate manual setup. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.9 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT20533
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-10
Closed date
2017-05-24
Last modified date
2017-05-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
RA00 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]