IBM Support

IT20124: INTEGRATION NODE ABENDS ON SHUTDOWN AFTER QMGR OUTAGE IF INTEGRATION NODE LISTENER NOT STARTED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • If a multi-instance integration node has been configured to run
    without starting the integration node HTTP Listener, it abends
    on a failover shutdown with the following abend stack:
    
    Windows:
    CommonServices!?lock@ImbMutex
    AdministrativeAgent!?stopHABrokerInstance@ImbBrokerDirector
    AdministrativeAgent!?runBrokerDirectorCleanup@ImbBrokerDirector
    AdministrativeAgent!?run@ImbBrokerDirector
    AdministrativeAgent!?start@ImbBrokerMain
    
    Unix:
    ImbBrokerDirector.ImbMutex::lock
    ImbBrokerDirector::stopHABrokerInstance()
    ImbBrokerDirector::runBrokerDirectorCleanup()
    ImbBrokerDirector::run()
    ImbBrokerMain::start
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus V9.0 and V10.0 who have the
    integration node HTTP listener disabled.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If the integration node HTTP listener has been disabled such
    that it does not run, an abend may occur if the integration node
    shuts down due to the associated MQ queue manager becoming
    unavailable.
    With IBM Integration Bus (IIB) V9.0 this will only occur if the
    integration node has been configured as a multi-instance or high
    availability (HA) node.
    With IIB V10.0 this may occur for HA and non-HA integration
    nodes if an associated MQ queue manager has been defined for the
    integration node.
    The abend occurs because the shutdown logic attempts to shutdown
    the integration node HTTP listener process without first
    checking that it is running.
    

Problem conclusion

  • The product now checks whether the HTTP Listener parameters have
    been set, denoting that it is running, before attempting to shut
    the process down.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.10
    v9.0       9.0.0.9
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20124

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0530

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-07

  • Closed date

    2017-08-31

  • Last modified date

    2017-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0530

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: