Error description
When trying to start PM on Brocade Access Gateway switches, you get the following error in the logs: 2017-03-05 18:14:34.728 HWNPM0286I Performance monitoring is unavailable for resource yyyyyyy (xxxxx) because the associated CIM agent does not have the required SMI-S support. 2017-03-05 18:14:34.775 HWNPM2128E The performance monitor for device yyyyyyyy (xxxxxx) is stopping due to an unexpected failure.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Spectrum Control 5.2.13 users that monitor Brocade AG * * Switches. * **************************************************************** * PROBLEM DESCRIPTION: * * Brocade AG Switches have Performance Monitoring Disabled. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fix is available in Spectrum Control 5.2.14.
Temporary fix
Comments
APAR Information
APAR number
IT19749
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
52C
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-17
Closed date
2017-04-28
Last modified date
2017-04-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0