Error description
When user application writes to a MM primary volume via flashcopy, it forces the MM to drop to Preparing state, which also forces session goes from 'Full Duplex' to 'Copy Pending' state. This leads to a Suspend code 13 (copy pending indication) sends to TPC-R server. TPC-R does not process this 13 code, so it gets handled internally as an unexpected suspend event rather than a duplex pending event - so a default freeze command was sent to the session (an unexpected behavior).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Tivoli Storage Productivity Center for Replication on z/OS * **************************************************************** * PROBLEM DESCRIPTION: * * When user application writes to a MM primary volume via * * flashcopy, it forces the MM to drop to Preparing state, * * which also forces session goes from 'Full Duplex' to 'Copy * * Pending' state. This leads to a Suspend code 13 (copy * * pending indication) sends to TPC-R server. TPC-R does not * * process this 13 code, so it gets handled internally as an * * unexpected suspend event rather than a duplex pending event * * - so a default freeze command was sent to the session (an * * unexpected behavior). * **************************************************************** * RECOMMENDATION: * * Recommend upgrading the Replication product to IBM Copy * * Services Manager. IBM Spectrum Control 5.2.x users who * * desire to use the Replication product functionality should * * upgrade to IBM Copy Services Manager. IBM Copy Services * * Manager is available with every IBM Spectrum Control V5.2.8 * * or later license. * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IT19630
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
527
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-15
Closed date
2017-06-19
Last modified date
2017-06-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"527"}]
Document Information
Modified date:
24 June 2022