Direct links to fixes
APAR status
Closed as program error.
Error description
A customer receives inbound files using CDSA to a mailbox that has encryption enabled. Restarting is disabled as a result of this. After the first file in the first CDSA session is received, then the second file is received. When this session breaks, CDSA stays in the 90 second socket retry timeout wait phase. During this phase, C:D UNIX sends the 2nd file successfully in the 2nd session. In S:I, the first file is stored to the mailbox. For the 2nd file (the restarted file), the routing fails with "Message ID not found". In the database, two messages show up both with the filename of the 1st successful file.
Local fix
STRRTC - 525067 CM / CM Circumvention: None
Problem summary
Users Affected: IBM Sterling B2B Integrator V5.2 Users Problem Description: Inbound message or data is lost into encrypted mailbox in the database after inbound CDSA session retry. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Delivered In: 5020601_7 5020602_4 5020603_2 5020500_16
Temporary fix
Comments
APAR Information
APAR number
IT19292
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-16
Closed date
2017-03-17
Last modified date
2017-07-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: