Error description

  • If the integration node's webadmin port is set to the default
    for the protocol (HTTP=80, HTTPS=443) then the browser will
    remove the port from a URL, which stops the WebUI from being
    displayed.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v10.0 using the web user
    interface (WebUI) with the webadmin port of the integration node
    set to the default for the protocol (HTTP=80, HTTPS=443)
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    An integration node's webadmin port is used in the URL to access
    the web user interface (WebUI). The webadmin port used can be
    changed, as documented in the Knowledge Center:
    http://www.ibm.com/support/knowledgecenter/en/SSMKHH_10.0.0/com.
    ibm.etools.mft.doc/bj23622_.htm.
    
    It is possible to set an integration node's webadmin port to 80
    on the HTTPConnector or 443 for the HTTPSConnector, which
    corresponds to the default HTTP and HTTPS port values. When a
    URL is specified in a browser that contains these default ports,
    the browser removes them from the URL.
    
    The WebUI is dependent on a port number being present in the
    browser URL, so if the WebUI is not passed a port number then a
    defect in the product means the WebUI is not displayed.
    

Problem conclusion

  • The product has been corrected so that if the WebUI is passed a
    URL that does not contain a port number, then depending on the
    protocol of the URL, the default port (HTTP=80, HTTPS=443) is
    assumed.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.7
    v9.0       9.0.0.8
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT17809

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-04

  • Closed date

    2016-11-23

  • Last modified date

    2017-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: