APAR status
Closed as program error.
Error description
FileInput stops polling remote directory over FTP/SFTP when it encounters BIP3380 java.net.SocketTimeoutException. The connection or timeout exception may be caused due to an intermittent network issue but after the network issue is resolved it is expected that the flow should resume polling remote directory again without having to restart the message flow.
Local fix
Restart message flow
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v9.0 and v10.0 using the FTP functionality of FileInput nodes. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: FileInput stops polling remote directory over FTP/SFTP when it encounters java.net.SocketTimeoutException. The connection error or timeout exception may be caused due to intermittent network issue. When such transient network issues are resolved the message flow should resume polling the remote directory again without having to restart the message flow. There are a number of resource name changes between WebSphere Message Broker and IBM Integration Bus Version 9.0. For details visit http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e tools.mft.doc/bb23814_.htm
Problem conclusion
The product has been updated such that a message flow restart is not required to resume polling the remote directory over FTP/SFTP after transient network errors. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.8 v9.0 9.0.0.8 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT17570
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-26
Closed date
2017-03-15
Last modified date
2017-03-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: