APAR status
Closed as program error.
Error description
If the MbXPath object from the Java Plugin Node API is used to reference or update a message using XPath expressions, it may cause the entire message to be parsed. If the message contains many repeating structures then this can cause the integration server (execution group) to terminate, due to a stack overflow and as such an abend file may not be written.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v10.0 using the MbXPath object from the Java Plugin Node API to parse an XML message that contains many repeating structures. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: The Java Plugin Node API has an MbXPath object which can be used to reference or update a XML message using XPath expressions. If the message contains many repeating structures and the XPath expressions cause all parts of a message to be parsed, this can cause the integration server (execution group) to terminate due to a stack overflow and as such an abend file may not be written.
Problem conclusion
Irrespective of how many repeating structures are parsed by an MbXPath object, the integration server will no longer terminate. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.7 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT17337
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-04
Closed date
2016-11-23
Last modified date
2016-11-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
RA00 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 March 2020