APAR status
Closed as program error.
Error description
If a database operation results in either an error or "success with info", the product will attempt to decode the text provided by the database driver in order to make it easier to diagnose failures. Due to a change introduced in 10.0.0.5 on the following codepages the converter required to translate the message to unicode is not recognised: cp932 windows-950 windows-936 KS_C_5601-1987 KSC_5601 0 for KS_C_5601-1989 0 for csKSC56011987 korean iso-ir-149 windows-949 TIS-620 This can result in the following error during initial connection to the database: BIP2132E: Invalid codepage '0' or conversion table 'ibm-0' missing or invalid.
Local fix
N
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus 10.0.0.5 or 10.0.0.6 using ODBC to connect to a database. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: If a database operation results in either an error or "success with info", the product will attempt to decode the text provided by the database driver in order to make it easier to diagnose failures. Due to a change introduced in 10.0.0.5 on the following codepages the converter required to translate the message to unicode is not recognised: cp932 windows-950 windows-936 KS_C_5601-1987 KSC_5601 0 for KS_C_5601-1989 0 for csKSC56011987 korean iso-ir-149 windows-949 TIS-620 This can result in the following error during initial connection to the database: BIP2132E: Invalid codepage '0' or conversion table 'ibm-0' missing or invalid. There are a number of resource name changes between WebSphere Message Broker and IBM Integration Bus Version 9.0. For details visit http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e tools.mft.doc/bb23814_.htm
Problem conclusion
IBM Integration Bus has been updated so that the error no longer occurs. Error text will be presumed to be CCSID 1208 if a codepage is unrecognised. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.7 v9.0 9.0.0.11 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT17162
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-22
Closed date
2016-11-23
Last modified date
2018-05-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 March 2020