IBM Support

IT16483: ADDING A ROLLUP SERVER IN IBM SPECTRUM CONTROL WILL FAIL IF THE SERVER PASSWORD IS LARGER THAN 15 CHARS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • User is unable to add  rollup server because the server password
    is >15 chars long.
    When he tries to add it a generic error SRV085593E is displayed.
    
    Error:
    2016-07-07 08:45:16.933+0000 HWN099993E TPCRuntimeException
    during Disk Manager service method execution
      com.ibm.tpc.common.api.TPCServerException: SRV085593E Unable
    to connect to repository database.
                 This type of error typically indicates that the
                 repository database has been shutdown. Please
                 ensure that your repository RDBMS is up and
    running.
    at com.ibm.tpc.rollup.SlaveServerMgmt.updateServer
    (SlaveServerMgmt.java:1033)
    at com.ibm.tpc.rollup.SlaveServerMgmt.addServer
    (SlaveServerMgmt.java:701)
    at com.ibm.tpc.disk.api.impl.DiskManagerService.addRollupServer
    (DiskManagerService.java:7474)
    
    When the trace is enabled a more specific error is displayed in
    the device logs:
    com.ibm.db2.jcc.am.SqlDataException: DB2 SQL Error:
    SQLCODE=-302,
    SQLSTATE=22001, SQLERRMC=null, DRIVER=3.65.77
    ....
    at com.ibm.db2.jcc.am.ko.executeUpdate(ko.java:760)
    at com.ibm.tpc.infrastructure.database.DBPreparedStatement.
    executeUpdate(DBPreparedStatement.java:261)
    at com.ibm.tpc.rollup.SlaveServerMgmt.updateServer
    (SlaveServerMgmt.java:1043)
    at com.ibm.tpc.rollup.SlaveServerMgmt.addServer
    (SlaveServerMgmt.java:701)
    at com.ibm.tpc.disk.api.impl.DiskManagerService.
    addRollupServer(DiskManagerService.java:7474)
    at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
    

Local fix

  • Run the following DB2 commands in a DB2 command window:
    db2 connect to TPCDB
    db2 set schema TPC
    db2 "ALTER TABLE T_RES_RU_SLAVE_SERVERS
    ALTER COLUMN PASSWORD SET
    DATA TYPE VARCHAR(125)"
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Spectrum Control 5.2.x users who add or edit rollup servers  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * User is unable to add rollup server if the server password   *
    * is longer than 15 chars.                                     *
    * When he tries to add it a generic error SRV085593E is        *
    * displayed.                                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0012 - target November 2016
    
    Fixed in IBM Spectrum Control 5.2.12.
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

  • Run the following DB2 commands in a DB2 command window:
    db2 connect to TPCDB
    db2 set schema TPC
    db2 "ALTER TABLE T_RES_RU_SLAVE_SERVERS
    ALTER COLUMN PASSWORD SET
    DATA TYPE VARCHAR(125)"
    

Comments

APAR Information

  • APAR number

    IT16483

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    52A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-08-05

  • Closed date

    2016-10-07

  • Last modified date

    2016-10-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

  • R52A PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52A"}]

Document Information

Modified date:
26 September 2021