Error description

  • Setting the HTTPConnector to an invalid value on the broker will
    cause a new execution group to fail to start.
    
    For instance issue:
    mqsichangeproperties MYBROKER -b httplistener -o HTTPConnector
    -n port -v @@MY_PORT@@
    
    and then create an execution group with:
    mqsicreateexecutiongroup MYBROKER -e MYEG
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v10.0 using the HTTP Input
    node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When using the console command mqsichangeproperties <BrokerName>
    -b httplistener -o HTTPConnector -n port -v <PortNumber>,
    PortNumber could be set to a non-integer value without causing
    an error.
    
    There are a number of resource name changes between WebSphere
    Message Broker and IBM Integration Bus Version 9.0.  For details
    visit
    http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e
    tools.mft.doc/bb23814_.htm
    

Problem conclusion

  • Checking of integer port inputs has been extended to check http
    listener port numbers, producing exception
    mqsi_integerArgumentRequired (BIP8068) if an invalid port is
    defined. This will prevent an execution group being created with
    an invalid port value, and failing to start.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.8
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT16331

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-27

  • Closed date

    2017-03-15

  • Last modified date

    2017-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
10 September 2020