Error description
DETAIL OF PROBLEM: After upgrade of TPC or Spectrum Control to version 5.2.10 Storage system probes begin to hang, which may cause subsequent scheduled Probe jobs to fail due to the hanging probes. Accessing the Web GUI may become problematic, especially when attempting to access Storage Device panels due to database locks caused by the Device server not releasing the lock placed on the database table while performing maintenance activity. Rebooting the server will temporarily restore access to the GUI until the next time a Storage System probe runs and locks the database. RECREATE STEPS: Upgrade an existing TPC or Spectrum Control environment actively monitoring SVC/Storwize devices to Spectrum Control v5.2.10. Allow scheduled Storage system Probe jobs to run and observe job run time increase with subsequent runs of the Probes beginning to fail. GUI usability degrades and Storage panels will no longer load. ________________________________________________________________ DB2 Version used for Server: N/A The defect is against component: 5608TPCA0 Server/Manager build/release (TPC): 5.2.10 ___________________________________________________ Problem as described by customer: Probe jobs taking many hours to complete (12-24hrs) when normally complete in 1 or 2 hours. Web GUI panels do not load and become unusable. Initial customer impact (low/med/high): high Local Fix: n/a
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.10 users * **************************************************************** * PROBLEM DESCRIPTION: * * Problems accessing the web UI. See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0011 - target August 2016 Fixed in IBM Spectrum Control 5.2.11. http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice. | MDVREGR | 5.2-TIV-TPC-RP0010 |
Temporary fix
Comments
APAR Information
APAR number
IT15885
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
52A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-06-27
Closed date
2016-08-04
Last modified date
2016-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DEVICE
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
R52A PSY
UP
Document Information
Modified date:
26 September 2021