Error description

  • There are two shared libraries each containing an XML schema.
    The two schemas have the same target namespace and contain
    elements or types with the same names.  An example would be
    that one schema is the next version of the other schema.
    
    A cast in a message map that references an element or type in
    one schema may be changed incorrectly to reference an element
    or type in the second schema when the map is saved and reopened
    in the mapping editor.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Toolkit v10 who create maps that
    use two message models where the two message models have the
    same target namespace and many named components with the same
    name but are different message models.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The Mapping editor fails to distinguish between two elements
    used in casts which have the same Qualified Name (QName) but
    come from two different schemas.
    

Problem conclusion

  • The Mapping editor now includes the schema when determining if
    two elements are identical.  Two elements must have the same
    Qualified Name (QName) and must come from the same schema in
    order for the two elements to be considered the same.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.6
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT15749

  • Reported component name

    IIB TOOLKIT

  • Reported component ID

    5724J0541

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-06-15

  • Closed date

    2016-08-17

  • Last modified date

    2016-08-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IIB TOOLKIT

  • Fixed component ID

    5724J0541

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
23 March 2020