IBM Support

IT15354: MANDATORY UDP IN SUB FLOW WITH NO VALUE ISN'T MARKED AS ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If a sub flow has a mandatory User Defined Prooperty (UDP) and
    the default value is set initially but then removed, there will
    be no validation error against the empty default value when the
    message flow is built..
    

Local fix

  • User can open subflow file in a text editor, look for the user
    defined property ( a <eStructuralFeatures... with attribute name
    is the property name), it has attribute defaultValueLiteral with
    empty value (defaultValueLiteral=""), remove this attribute and
    save the file. The flow file builder will now mark the error to
    the file.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Toolkit v9.0 and v10.0 using the
    flow editor to define a mandatory user defined property (UDP) in
    a sub flow.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If user provides a default value to a mandatory user defined
    property (UDP) in a subflow, and removes the default value later
    using the flow editor, the default value attribute is still kept
    in the file and the value is empty. When the flow builder
    validates the message flow, the mandatory UDP has an empty value
    as its default value, so the message flow file is not marked
    with any error.
    

Problem conclusion

  • The toolkit now will remove the default value attribute from the
    flow file if user set the default value to an empty string. The
    flow builder will mark the message flow file with an error if a
    mandatory UDP doesn't have default value.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.6
    v9.0       9.0.0.6
    
    The latest available maintenance can be obtained from:
    'Recommended fixes for WebSphere Message Broker Toolkit'
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27009742
    
    If the maintenance level is not yet available, information on
    its planned availability can be found in 'WebSphere Message
    Broker Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT15354

  • Reported component name

    IB TOOLKIT

  • Reported component ID

    5724J0531

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-19

  • Closed date

    2016-06-09

  • Last modified date

    2016-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IB TOOLKIT

  • Fixed component ID

    5724J0531

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
23 March 2020