Fixes are available
APAR status
Closed as program error.
Error description
GatewayScript urlopen function response.headers output is not correct when header is non-coalesced. When there is non-coalesced header such as 'Set-Cookie' with two values: 'Cookie1=value1' and 'Cookie2=value2', GatewayScript urlopen response.headers will return { 'Set-Cookie': 'Cookie2=value2' }, which is not correct. urlopen response.headers should return array for non-coalesced header, such as { 'Set-Cookie': ['Cookie1=value1', 'Cookie2=value2'] }.
Local fix
Problem summary
GatewayScript urlopen response.headers output is not correct when header is non-coalesced.
Problem conclusion
The fix will be in 7.0.0.14, 7.1.0.11, 7.2.0.8, 7.5.0.1
Temporary fix
Comments
APAR Information
APAR number
IT14875
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-04-20
Closed date
2016-04-28
Last modified date
2016-08-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R750 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: