Error description

  • During the TimeoutNotification node flow startup the node scans
    its internal timeout store and expects to send Notifications
    only for any persistent timeout requests that are now past and
    that have the IgnoreMissed property value set to False. But the
    node ignores the IgnoreMissed property value and it sends
    Notifications for timeout requests that are configured with
    IgnoreMissed property value set to 'TRUE' as well.
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus V10.0 using the Timeout
    Notification node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    During the TimeoutNotification node startup, the node scans its
    internal timeout store and expects to send Notifications only
    for persistent timeout requests that are now past and that have
    the IgnoreMissed property value set to False. But the node
    ignores the IgnoreMissed property value and it sends
    Notifications for timeout requests that are configured with
    IgnoreMissed property value set to 'TRUE' as well.
    
    There are a number of resource name changes between WebSphere
    Message Broker and IBM Integration Bus Version 9.0.  For details
    visit
    http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e
    tools.mft.doc/bb23814_.htm
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT14750

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-04-12

  • Closed date

    2016-11-23

  • Last modified date

    2016-11-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]