APAR status
Closed as program error.
Error description
If a message flow references a certain type of file that has no report generator defined, the document generator throws a NullPointerException (NPE).
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Toolkit v10.0 who generate documentation on WSDL files or message flow files, which reference a WSDL file. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: The "Generate documentation" function supports only mxsd and message set. If a user tries to generate a document for a WSDL which references a XML Schema (XSD), the function will not be able to find the associated generator and it will throw a NullPointerException.
Problem conclusion
The "Generate documentation" function has been modified to check for the existence of the generator and will no longer throw a NullPointerException. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.5 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT14396
Reported component name
IIB TOOLKIT
Reported component ID
5724J0541
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-31
Closed date
2016-05-26
Last modified date
2016-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
IIB TOOLKIT
Fixed component ID
5724J0541
Applicable component levels
RA00 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]