IBM Support

IT14379: DATA SOURCE (CIMOM) CREDENTIALS STORED/USED BY TPC AFTER BEING REMOVED AND RE-ADDED WITH AN UPDATED ID/PASSWORD.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Probes and performance monitor jobs fail referencing incorrect
    username/password despite confirming both are correctly entered
    in the Spectrum Control GUI.  Failure messages such as the
    following are found in probe job logs:
    2016-03-09 05:44:51.922-0700 HWN021538E The username <username>
    or password is wrong on CIMOM https://storage.example.com:5989
    This is caused by invalid credentials that should have been
    removed from the Spectrum Control database tables when a
    previous data source (CIMOM) was removed and/or updated.  Probes
    can still refer to the invalid info and the jobs will fail as
    noted.
    RECREATE STEPS:
    Remove a switch or subsystem and re-add it with new data source
    credentials, observe probe failures as noted
    ________________________________________________________________
    DB2 Version used for Server:    N/A
    The defect is against component:   5608TPCA0
    Server/Manager build/release (TPC):   5.2.8
    
    ________________________________________________________________
    Problem as described by customer:   Probe/Performance monitor
    failure
    Initial customer impact (low/med/high): med
    

Local fix

  • Contact support for validation of the problem via database table
    queries.  Once confirmed, removing all monitored devices that
    are associated with that CIMOM data source and adding them back
    in clears the errant database table entry, and configures probes
    and performance monitor jobs to refer to the correct
    credentials.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control 5.2.8 and 5.2.9 users who have added    *
    * multiple CIMOM data sources for devices, possibly after the  *
    * original data source was no longer reachable.                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.  The error can be      *
    * ignored if the other data source is successful.  However, it *
    * does cause the status of the probe to be marked as having an *
    * error.                                                       *
    ****************************************************************
    

Problem conclusion

  • This APAR fixes the issue of the probe ending in failure in this
    case of multiple data sources (1 successful and 1 failure).
    Further refinement for multiple data sources is targeted for a
    future release.
    
    The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0010 - target 2Q16
    Fixed in IBM Spectrum Control 5.2.10.
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    
    | MDVREGR 5.2-TIV-TPC-RP0008 |
    | MDVREGR 5.2-TIV-TPC-RP0009 |
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT14379

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    528

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-18

  • Closed date

    2016-03-28

  • Last modified date

    2016-03-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABRIC
    

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

  • R528 PSY

       UP

  • R529 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"528","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information