IBM Support

IT13639: WSA ADDRESSING REFERENCEPARAMETERS NOT RECOGNIZED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using WSA, the ReferenceParameters are not recognized and
    are not copied to the local environment.  This was
    regressed in WebSphere Message Broker 8.0.0.5 when the WAS thin
    client was changed from 7.0.0.29 to 8.5.5.1.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of WebSphere Message Broker V8.0 and IBM Integration
    Bus V9.0, and WS-Addressing and ReferenceParameters.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When using WS-Addressing the ReferenceParameters in the header
    are not recognised and
    are not copied to the local environment.  This was regressed in
    8.0.0.5 when the WAS thin client was changed from
    7.0.0.29 to 8.5.5.1.  The WAS APAR that fixes this issue is
    PM78282 and is contained in 8.5.5.2.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT13639

  • Reported component name

    WEB MESSAGE BRO

  • Reported component ID

    5724J0520

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-02-05

  • Closed date

    2016-03-01

  • Last modified date

    2016-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEB MESSAGE BRO

  • Fixed component ID

    5724J0520

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSKM8N","label":"WebSphere Message Broker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
01 March 2016