IT13445: CONTINUOUS RUNNING PROBES TO STORAGE DEVICES IN V.5.2.8

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Large number of storage device (i.e.SVC, Storwize, FlashSystem)
    bellwether events trigger continous running probes in IBM
    Spectrum Control v.5.2.8
    
    
    
    Investigation into the handling of event-triggered full
    probes and an increase of the individual event limit when a
    bellwether event is sent by the storage device.
    
    In addition the probe cool-down period at the TPC server
    requires adjustment.
    
    RECREATE STEPS:
    Upgrade to v.5.2.8 and monitor probe runs to applicable storage
    devices.
    ________________________________________________________________
    DB2 Version used for Server: N/A
    The defect is against component: 5608TPC00
    Server/Manager build/release (TPC): 5.2.8
    ________________________________________________________________
    Problem as described by customer: Storage Probes restart
    constantly
    Initial customer impact (low/med/high): high
    

Local fix

  • Contact Support
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC 5.2.7 and 5.2.8 users monitoring SVC or Storwize storage *
    * may experience many (and maybe continuous) extra probes      *
    * being run outside of the schedule.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Events received from the storage devices are causing         *
    * additional probes to pick up updates.  See ERROR             *
    * DESCRIPTION.                                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • The full probes based on bellwether events will be limited to
    twice daily.  Manual probes can be run between the scheduled
    probes if additional updates are needed.  The following two
    properties were set:
    
    NAPI.SVCEventThreshold = 500
    NAPI.SVCFullprobeCooldown = 720
    
    The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0009 - target February 2016
    
    Fixed in IBM Spectrum Control 5.2.9.
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT13445

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-01-29

  • Closed date

    2016-02-03

  • Last modified date

    2016-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DISK
    

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

  • R528 PSY

       UP

  • R527 PSY

       UP