Fixes are available
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
APAR status
Closed as program error.
Error description
Large number of storage device (i.e.SVC, Storwize, FlashSystem) bellwether events trigger continous running probes in IBM Spectrum Control v.5.2.8 Investigation into the handling of event-triggered full probes and an increase of the individual event limit when a bellwether event is sent by the storage device. In addition the probe cool-down period at the TPC server requires adjustment. RECREATE STEPS: Upgrade to v.5.2.8 and monitor probe runs to applicable storage devices. ________________________________________________________________ DB2 Version used for Server: N/A The defect is against component: 5608TPC00 Server/Manager build/release (TPC): 5.2.8 ________________________________________________________________ Problem as described by customer: Storage Probes restart constantly Initial customer impact (low/med/high): high
Local fix
Contact Support
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.7 and 5.2.8 users monitoring SVC or Storwize storage * * may experience many (and maybe continuous) extra probes * * being run outside of the schedule. * **************************************************************** * PROBLEM DESCRIPTION: * * Events received from the storage devices are causing * * additional probes to pick up updates. See ERROR * * DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The full probes based on bellwether events will be limited to twice daily. Manual probes can be run between the scheduled probes if additional updates are needed. The following two properties were set: NAPI.SVCEventThreshold = 500 NAPI.SVCFullprobeCooldown = 720 The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0009 - target February 2016 Fixed in IBM Spectrum Control 5.2.9. http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT13445
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-01-29
Closed date
2016-02-03
Last modified date
2016-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DISK
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
R528 PSY
UP
R527 PSY
UP
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510"}]