IBM Support

IT12996: TIMEOUTNOTIFICATION NODE DOESNT PROPAGATE A BLANK MESSAGE TREE WHEN RUNNING IN CONTROLLED MODE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When a blank message is being put to TimeoutControl node,
    theTimeoutNotification node fails to propagate the message to
    its out terminal. Ideally, it is expected that the
    TimeoutNotification node propagates a message tree containing
    only a Properties folder when there is no message body
    available.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus V10.0 with TimeoutNotification
    Node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When a blank message is being put to TimeoutControl node,
    theTimeoutNotification node fails to propagate the message to
    its out terminal. Ideally, it is expected that the
    TimeoutNotification node propagates a message tree containing
    only a Properties folder when there is no message body
    available.
    
    The problem is observed only when the Operation mode property
    value on the TimeoutNotification node is configured as "
    Controlled".
    
    <i>There are a number of resource name changes between WebSphere
    Message Broker and IBM Integration Bus Version 9.0.  For details
    visit
    http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e
    tools.mft.doc/bb23814_.htm</i>
    

Problem conclusion

  • The TimeoutNotification Node no longer fails to propagate an
    empty message when the Operation Mode property is set to
    'Controlled'.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.4
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT12996

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-01-04

  • Closed date

    2016-03-07

  • Last modified date

    2016-03-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
23 March 2020