IT10159: THE PATH PORT PAIRING FILE ONLY WORKS CORRECTLY IF THE HEX LSS VALUE IS LOWER CASE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During establish path TPC-R compares all LSS-LSS pairs in the
    Derby database with what's in the portpairing.csv file, if the
    hex value of the LSS value (hex A - F), is lower case in the LSS
     pair info in the Derby database, but the portpairing.csv has it
     upper case, then no LSS element is returned to the function.
    The result of that is the paths will not be setup properly:
    > 2107.DDYYY-0x90-2107.EEXXX-0xB8 is not equal
    2107.DDYYY-0x90-2107.EEXXX-0xb8
    This problem may also extends to port values having upper case
    hex string in the .csv file
    The workaround is to fill in the HEX LSS value in lower case in
    the portpairing.csv
    

Local fix

  • The workaround is to fill in the HEX Lss value in lower case in
    the portpairing.csv
    

Problem summary

  • Users that set up the path port pairing between LSS's that have
    hex characters >9 and assign lower case values
    

Problem conclusion

  • | fix pack | 5.2.7-TIV-TPC-FP0000 - target 3Q 2015 |
    
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future fix packs do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    
    Customers setting the path port pairing between LSS's that have
    hex characters >9 and assign lower case values will experience a
    problem when trying to establish paths automatically. These
    paths will fail and not be created.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT10159

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-07-21

  • Closed date

    2015-07-31

  • Last modified date

    2015-07-31

  • APAR is sysrouted FROM one or more of the following:

    PI44198

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWFB4","label":"IBM Spectrum Control Standard Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
05 October 2023