APAR status
Closed as program error.
Error description
During validation of a message the execution group can abend with the following calls at the top of the Abend stack: BIPNVBRT!XMLStringBuffer_addString+0x43 BIPNVBRT!Instructions_readSimpleTypeHandleEndElementEvent+0x212 NLN:487> BIPNVBRT!VMContext_handleEndElementEvent+0x12b BIPNVBRT!VMScannerEventQueue_produceEndElementEvent+0x5e >
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus V9.0 validating messages in the XMLNSC domain where an empty default value is used. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: During validation of a message where am empty default value is applied (e.g. ) the execution group can abend with the following calls at the top of the Abend stack: BIPNVBRT!XMLStringBuffer_addString+0x43 BIPNVBRT!Instructions_readSimpleTypeHandleEndElementEvent+0x212 BIPNVBRT!VMContext_handleEndElementEvent+0x12b BIPNVBRT!VMScannerEventQueue_produceEndElementEvent+0x5e There are a number of resource name changes between WebSphere Message Broker and IBM Integration Bus Version 9.0. For details visit http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e tools.mft.doc/bb23814_.htm
Problem conclusion
The product includes a version of the XLXP-C component that fixes this issue. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v9.0 9.0.0.6 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT06302
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-01-05
Closed date
2015-01-30
Last modified date
2016-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: