IBM Support

IT05551: DBACCESS CAN CORE DUMP ON EXIT AFTER THE ERROR -801 HAS OCCURRED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • On HPUX IA64 11.31, IBM Informix DB-access utility can core dump
    on exit.
    
    The issue can happen after SQL edit buffer in dbaccess is
    completely filled up with text resulting in error -801, then
    exit dbaccess the following message is returned to the command
    prompt:
    
         Database closed.Memory fault(coredump)
    
    The core file generated by dbaccess has the stack below:
    
    # gdb $INFORMIXDIR/bin/dbaccess core
    ..
    Core was generated by `dbaccess'.
    Program terminated with signal 11, Segmentation fault.
    SEGV_MAPERR - Address not mapped to object
    #0  :1 in real_free+0x7e1 () from /usr/lib/hpux64/libc.so.1
    (gdb) where
    #0  real_free+0x7e1 () from /usr/lib/hpux64/libc.so.1
    #1  _free+0xe0 () from /usr/lib/hpux64/libc.so.1
    #2  free+0x2d0 () from /usr/lib/hpux64/libc.so.1
    #3  meFree () at osmutex.c:639
    #4  sqlCSfree () at asfutil.c:814
    #5  pfDiscon () at asfpfsqi.c:4028
    #6  cmDiscon () at cm.c:1074
    #7  ascRelease () at al.c:489
    #8  ASF_Call () at asfapi.c:560
    #9  asf_disconnect () at iqconnct.c:1571
    #10 disconnect () at iqconnct.c:1644
    #11 disconnect_single () at iqconnct.c:3225
    #12 sqli_connect_close () at iqconnct.c:1929
    #13 exdiscnnct () at rsqcnnct.ec:570
    #14 discnnct_dbenv () at rsqcnnct.ec:763
    #15 menus () at rsqmain.c:595
    #16 main () at rsqmain.c:330
    (gdb)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users.                                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IBM Informix Server 11.70                          *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IBM Informix Server 11.70
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT05551

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-11-13

  • Closed date

    2017-06-09

  • Last modified date

    2017-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

  • RB70 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B70","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
09 June 2017