Error description
Brocade has added a new OUI value which is not recognized by TPC. Because of this information for these switches and their fabrics is not collected as expected resulting in functional limitations. This problem may be encountered with TPC or IBM System Director and VMcontrol. Here are some sample errors that can be seen with TPC or VMcontrol. These errors occur when there is a Brocade CIMOM agent already configured and monitoring the switches. The following samples of messaging may be found in the IBM System Director (VMcontrol) error-log-0.html: INFO Unable to start zoning transaction for fabricID: 100050EB1Axxxxxx com.ibm.tpc.common.api.TPCServerException: BTAFM4501E No agent is available to configure the zoning on the fabric with ID 100050EB1Axxxxxx Failed to start transaction on fabric 100050EB1Axxxxxx. Check connection to switch(es) The following error may show up in TPC msgTPCDeviceServer.log: BTAFM4501E No agent is available to configure the zoning on the fabric with ID 100050EB1Axxxxxx. com.ibm.tpc.fabric.FabricManagerService startTransaction The following error may show up in the TPC msgprobeFabric.xxxxxxx.log if a Fabric contains switches with both known and unknown OUI values: BTADS0083W Some or all information may not be collected for fabric/fabrics since agent/agents are not configured and/or not currently operational. Fabric probe for fabric 10000027F80XXXXXX has some limitations. For switch 100050EB1AXXXXXX following the information will not be collected - Active Zone Configuration Information, Full Zone Database Information.
Local fix
Log into server with db2admin or db2inst1 (or equivalent, depending on platform) connect to TPCDB db2 connect to TPCDB db2 set schema tpc db2 "insert into T_RES_OUI values ('50EB1A','Brocade')" Initiate Fabric discovery in TPC or (VMcontrol Farm and Switch inventory)
Problem summary
Users Affected: TPC 4.2.2 users with Brocade fabrics Problem Description: See ERROR DESCRIPTION.
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | fix pack | 4.2.2-TIV-TPC-FP0007 http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT03238
Reported component name
TPC STANDARD ED
Reported component ID
5608TPCS0
Reported release
422
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-17
Closed date
2014-07-31
Last modified date
2014-07-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC STANDARD ED
Fixed component ID
5608TPCS0
Applicable component levels
R422 PSY
UP