IBM Support

IT00970: ONSMSYNC -G CAN CRASH WHEN THE VALUE SPECIFIED IS LESS THAN TOTAL NUMBER OF L0 ARCHIVE ENTRIES IN IXBAR FILE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • onsmsync -g command can crash when the value specified
    represents the number of generations/versions of level 0 backup
    to retain is less than the total number of L0 archive entries
    that exist in the ixbar file.
    
    For example:
    When the total number of L0 backup entries in ixbar is 10.
     Then running the following commands will end up either complete
    successfully, or crash
      - onsmsync -g 11; onsmsync -g 10, ... complete
      - onsmsync -g 9; onsmsync -g 8, ... crash
    
    
    The crash generated the details following:
    
    Problem signature:
      Problem Event Name: APPCRASH
      Application Name: onsmsync.exe
      Application Version: 0.0.0.0
      Application Timestamp: 522025b9
      Fault Module Name: libbsapsm.dll
      Fault Module Version: 0.0.0.0
      Fault Module Timestamp: 52202560
      Exception Code: c0000005
      Exception Offset: 0000000000001550
      OS Version: 6.1.7600.2.0.0.274.10
      Locale ID: 1033
      Additional Information 1: 33b6
      Additional Information 2: 33b69c729bea78e5e5533fef0224a957
      Additional Information 3: e309
      Additional Information 4: e30959ae26d8044b0e2616ca32666cd8
    
    
    It also placed a lock on PSM catalog table, and this locking can
    prevent next onbar/onsmsycn to run. To unlock run "onpsm -C
    unlock".
    
    
    C:\IBM\Informix\12.10>onpsm -C detail
    
    Informix Primary Storage Manager State:
    
        PSM Unique ID    : 1396504950
        Catalog Location : C:\IBM\Informix\12.10\etc\psm\
        Catalog State    : Locked
        Catalog Owner    : 110
        Catalog Lock Mode: Regular
    
    
    Sessions:
        Session ID       Process ID
        110              2856
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * This problem is seen on Windows only with onbar and PSM.     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * onsmsync expiration of objects in PSM storage manager on     *
    * Windows was not working correctly -- onsmsync was crashing.  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IDS-12.10.xC3                                      *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IDS-12.10.xC3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT00970

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-10

  • Closed date

    2014-11-07

  • Last modified date

    2014-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

  • RC10 PSN

       UP

  • RC10 PSY

       UP