Error description
When one AssemblyLine starts and runs another AssemblyLine in manul mode, and the other AssemblyLime evaluates parameters with JavaScript, then the first AssemblyLine will get the "task" object set to null.
Local fix
NA
Problem summary
The "task" object should not be null.
Problem conclusion
This is a bug in the TDI code and has been fixed. The official fix would be made available in 7.1.1-TIV-TDI-FP0003. A LAIF fix 7.1.1-TIV-TDI-LA0003 will also be released.
Temporary fix
Comments
APAR Information
APAR number
IO17707
Reported component name
ITDI MULTIPLATF
Reported component ID
5724D9960
Reported release
711
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-11
Closed date
2012-12-11
Last modified date
2012-12-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITDI MULTIPLATF
Fixed component ID
5724D9960
Applicable component levels
R71D PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.