IO17519: FORM EDITOR MODE ISSUE

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • After customizing a field on the form via the Form editor to
    specify a
    mode of  visibility for a Field AND then removing the mode type
    the
    field is no longer visible in any mode.
    The expected result is that it should be reset to the default
    visibility
    for all modes.
    
    STEPS TO DUPLICATE:
    
    1.  Create a custom connector
    2.  Open with Form Editor
    3.  Add a Field,  Set Mode Selection to AddOnly
    4.  and add to General form
    5.  Save and close
    6.  Add to an AL in various modes to test visibility.
    7.  Go back to the form editor and remove AddOnly
    8.  Save and Close
    9.  Go back to an AL and test, the field is no longer visible in
    any
    mode.
    
    The manual fix is to open the .connector and remove the line:
    
        <parameter name="modes"/>
    
    from the definition:
    
    <FormItem name="filepath">
                <parameter name="description">Enter path</parameter>
                <parameter name="label">Path</parameter>
                <parameter name="modes"/>
            </FormItem>
    
    Desired Behavior:  Form Mode is managed correctly after changes
    in
    visibility from the Form Editor.
    
    Environment: TDI 7.0. fp 6  (and later)
    
    Note this fix needs to be applied to 7.0 and later.
    

Local fix

  • 1762
    

Problem summary

  • Form mode should behave properly.
    

Problem conclusion

  • This is a bug in the TDI Code and has been fixed. The official
    fix will be made available in 7.1.0-TIV-TDI-FP0008.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IO17519

  • Reported component name

    ITDI MULTIPLATF

  • Reported component ID

    5724D9960

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-08

  • Closed date

    2012-12-04

  • Last modified date

    2012-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IO17876 IO17877

Fix information

  • Fixed component name

    ITDI MULTIPLATF

  • Fixed component ID

    5724D9960

Applicable component levels

  • R710 PSY

       UP



Rate this page: