APAR status
Closed as program error.
Error description
Error Message: The JVM crashes with segmentation fault. . Stack Trace: One posible stack trace: javax/swing/text/AbstractDocument$DefaultDocumentEvent.addEdit(A bstractDocument.java:2777) javax/swing/text/DefaultStyledDocument$ElementBuffer.create(Defa ultStyledDocument.java:1493) javax/swing/text/DefaultStyledDocument.create(DefaultStyledDocum ent.java:160) javax/swing/text/html/HTMLDocument.create(HTMLDocument.java:480) javax/swing/text/html/HTMLDocument$HTMLReader.flushBuffer(HTMLDo cument.java:3747) javax/swing/text/html/HTMLDocument$HTMLReader.flush(HTMLDocument .java:2549) javax/swing/text/html/HTMLEditorKit.read(HTMLEditorKit.java:273) Note: This problem can occur in other methods. This problem can only happen on z Systems z196 or later hardware. This problem was introduced in Java 8 SR5. .
Local fix
This crash can be avoided if the -Xjit:disableSynchronizedFieldLoad is used.
Problem summary
A crash can happen in Java JIT compiled code when the synchronized field load optimization is enabled. This optimization fails to sign extend a 32-bit object field after loading it from memory. A value without proper sign extension can contain garbage in the high order and lead to segmentation faults should it be used to address memory.
Problem conclusion
The JIT compiler has been updated to prevent the crash from occurring when loading 32-bit Java object fields in synchronized regions. . This APAR will be fixed in the following Java Releases: 8 SR5 FP20 (8.0.5.20) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ07725
Reported component name
JIT
Reported component ID
620700124
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-10
Closed date
2018-07-10
Last modified date
2018-08-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JIT
Fixed component ID
620700124
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
31 August 2018