Error description
Error Message: Could not obtain the algorithm for SHA-512/RSA . Stack Trace: com.ibm.security.pkcsutil.PKCSException: Could not obtain the algorithm for SHA-512/RSA at com.ibm.security.pkcs7.SignerInfo.verify(SignerInfo.java:1342) at com.ibm.security.pkcs7.SignerInfo.verify(SignerInfo.java:1194) at com.ibm.security.pkcs7.SignerInfo.verify(SignerInfo.java:1170) at com.ibm.security.pkcs7.SignedData.verify(SignedData.java:1333) at com.ibm.security.pkcs7.SignedData.verify(SignedData.java:1248) at Pkcs7.main(Pkcs7.java:37) . The problem does not occur with IBM SDK 7.
Local fix
Problem summary
While converting Object Identifiers (OIDs) to algorithm names, the IBMPKCS module returned algorithm names that were not supported by IBMJCE and IBMJCEFIPS crypto providers.
Problem conclusion
The IBMJCE, IBMPKCS11Impl and IBMPKCS have been modified to return algorithm names that are compatible with IBMJCE. The associated Hursley RTC Problem Reports are 137729, 137776 The associated Austin CMVC defects are 117830, 117839 JVMs affected: Java 8.0 The fix was delivered for Java 8 SR5FP15 The affected jars are ibmpkcs.jar, ibmjceprovider.jar and ibmpkcs11impl.jar The build level of this jar for the affected releases is 20180410 . This APAR will be fixed in the following Java Releases: 8 SR5 FP15 (8.0.5.15) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ05530
Reported component name
SECURITY
Reported component ID
620700125
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-06
Closed date
2018-05-10
Last modified date
2018-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SECURITY
Fixed component ID
620700125
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"270","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
07 December 2020