IBM Support

IC99392: DIFFERENT TPC COMPONENTS REFERENCE DIFFERENT JDBC DRIVER FILES IN DIFFERENT LOCATIONS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Currently, the various TPC components access the DB2-based TPCDB
    database repository using different driver files in different
    locations.  Certain components bundle the db2jcc.jar driver file
    within the TPC installation directories while others refer to
    the OS classpath which should be configured to the db2jcc.jar
    file located with the DB2 instance.
    Situations beyond the control of TPC software have exposed that
    its sometimes possible for the OS classpath to not get updated
    when DB2 is upgraded and/or reinstalled.  For example the TPC
    Data Server process sets a dynamic classpath variable when
    started and if this hard-coded variable points to a location
    that no longer exists, the TPC Data Server process will fail to
    start.
    Troubleshooting this current, mixed configuration is not a
    straightforward process and typically requires product
    development to be engaged.  This APAR changes the TPC design to
    refer to one, centralized DB2 JDBC driver.  This simplifies
    diagnosis of database communication related problems and reduces
    redundancy.
    RECREATE STEPS:
    Varied
    ________________________________________________________________
    DB2 Version used for Server:    10.1
    The defect is against component:   5608TPC00
    Server/Manager build/release (TPC):   5.2.0.0
    Agent build/release (TPC):    N/A
    Server/Manager (OS):     N/A
    Agent (OS):       N/A
    ________________________________________________________________
    Problem as described by customer:   Data server won't start
    after DB2 upgrade
    Initial customer impact (low/med/high): med
    

Local fix

  • Varied
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC 5.2.0 users                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • A common JDBC driver will be used in TPC.  The fix for this APAR
    is targeted for the following maintenance package:
    
    | refresh pack | 5.2-TIV-TPC-RP0001 - target March 2014
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs or fix packs do not
    represent a formal commitment by IBM. The dates are subject to
    change without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC99392

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-02-14

  • Closed date

    2014-03-03

  • Last modified date

    2014-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DB
    

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

  • R520 PSY

       UP