Fixes are available
Refresh Pack 5.2.2 (June 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.3 (August 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
Currently, the various TPC components access the DB2-based TPCDB database repository using different driver files in different locations. Certain components bundle the db2jcc.jar driver file within the TPC installation directories while others refer to the OS classpath which should be configured to the db2jcc.jar file located with the DB2 instance. Situations beyond the control of TPC software have exposed that its sometimes possible for the OS classpath to not get updated when DB2 is upgraded and/or reinstalled. For example the TPC Data Server process sets a dynamic classpath variable when started and if this hard-coded variable points to a location that no longer exists, the TPC Data Server process will fail to start. Troubleshooting this current, mixed configuration is not a straightforward process and typically requires product development to be engaged. This APAR changes the TPC design to refer to one, centralized DB2 JDBC driver. This simplifies diagnosis of database communication related problems and reduces redundancy. RECREATE STEPS: Varied ________________________________________________________________ DB2 Version used for Server: 10.1 The defect is against component: 5608TPC00 Server/Manager build/release (TPC): 5.2.0.0 Agent build/release (TPC): N/A Server/Manager (OS): N/A Agent (OS): N/A ________________________________________________________________ Problem as described by customer: Data server won't start after DB2 upgrade Initial customer impact (low/med/high): med
Local fix
Varied
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.0 users * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
A common JDBC driver will be used in TPC. The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0001 - target March 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC99392
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-14
Closed date
2014-03-03
Last modified date
2014-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DB
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
Document Information
Modified date:
23 March 2022