IBM Support

IC98895: TIMESERIES VTI SCANCOST FUNCTION IS FIXED AND MAKES NO REFERENCE TO THE PASSED IN QUALIFIER TO DETERMINE THE REAL COST

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • An access to a VTI timeseries table adds a fixed number to the
    optimizer costs.
    
    The optimizer doesn't consider if there could be an effective
    composite index access to the VTI
    (using the primary key of the base table) or that an access with
    "timestamp = date" is very effective too.
    
    This could lead to very ineffective query plans.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * users of timeseries vti                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IDS-12.10.xC4                                      *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IDS-12.10.xC4
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC98895

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-22

  • Closed date

    2014-11-07

  • Last modified date

    2014-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

  • RC10 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: