IBM Support

IC98506: TPC FABRIC PROBE ON SRA WILL FAIL WHEN THE DOMAIN NAME IN TPC DATABASE IS AN EMPTY STRING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Fabric probe may fail on the SRA if the Domain name
    cannot be retrieved:
    
    The problem occurs when T_RES_HOST.DOMAIN_NAME is a blank (' ').
    Because of this a dot ('.') + blank are added to the hostname
    The TPC Server cannot reach the SRA service with hostname
    'WIN-HOSTNAME-EXAMPLE. '
    
    Error messages (Example):
    Server trace file:
    Failed to connect to WIN-HOSTNAME-EXAMPLE. :9567
    
    Error  ... BTADS0032E   Inband Scanner TopologyOnly failed on
       agent xxx.xxx.xxx.xxx with Return Code 47 .
    Error  ... BTADS0024E   Error encountered processing scanner
       TopologyOnly data from agent xxx.xxx.xxx.xxx.
    Warning  ... BTADS0082W First run of probe using a subset of
       agents to probe fabric/fabrics failed.
    
    (The error BTADS0032E is generic and may be caused by other
    issues, too)
    
    RECREATE STEPS:
    Deploy an SRA that manages at least one Fabric and run Fabric
    probes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC 5.2.0 users running fabric probes                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0001 - target March 2014
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs or fix packs do not
    represent a formal commitment by IBM. The dates are subject to
    change without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC98506

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-12-27

  • Closed date

    2014-02-04

  • Last modified date

    2014-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABRIC
    

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

  • R520 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: