Fixes are available
Refresh Pack 5.2.2 (June 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.3 (August 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
The Jazz Service Management and Tivoli Common Reporting installation for TPC may fail in a specific installation or upgrade scenario. The following messages are seen in the traceTPCInstall.log: 2013-11-21 16:00:58.439+0100 INFO stderr= CTGTRI164E Processing has failed. See the following error message for details: 2013-11-21 16:00:58.464+0100 INFO QE-DEF-0285 The logon failed. 2013-11-21 16:00:58.466+0100 ERROR com.ibm.tpc.install.frontend.ia.actions.StatusUpdater targetFinished org.apache.tools.ant.BuildException BPCIN0069E Errors occurred during the configuration of Tivoli Common Reporting for Tivoli Storage Productivity Center. Review the log files for more information. In the same log file, we can see: 2013-11-18 23:39:32.503+0100 INFO Executing 'ln' with arguments: '-s' '/opt/ibm/db2/V9.7/lib32/libdb2.so' '/opt/IBM/JazzSM/reporting/cognos/bin/ TPC upgrade error at the TCR component is generated by the wrong value of the varDBPath variable from the Install configuration files. It's occurred because DB2 was upgraded from version 9.7 to 10.1 after the TPC 5.2.0 upgrade/installation. The value of the varDBPath variable was not synchronized with the new path of the DB2 Installation. This scenario only applies for UNIX platform. steps to reproduce the issue: ============================= - DB2 9.7 is installed - TPC 5.2 is installed or was upgraded - DB2 is upgraded in version 10.1 - Install JazzSM/TCR Initial Impact: Med
Local fix
Update the varDBPath variable in the installVariable.properties file. or Remove or rename the DB2 9.7 directory (default is /opt/ibm/db2/V9.7) and reboot the machine.
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.0 users * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. Follow LOCAL FIX * * instructions until the fix is available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0001 - target March 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC98140
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-05
Closed date
2014-01-14
Last modified date
2014-01-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INSTALL
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
Document Information
Modified date:
23 March 2022