Fixes are available
Refresh Pack 5.2.2 (June 2014) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.5 (July 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.3 (August 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4 (November 2014) for Tivoli Storage Productivity Center
Fix Pack 5.2.4.1 (December 2014) for Tivoli Storage Productivity Center
Refresh Pack 5.2.5 (March 2015) for Tivoli Storage Productivity Center (withdrawn)
Fix Pack 5.1.1.6 (March 2015) for Tivoli Storage Productivity Center
Fix Pack 5.2.5.1 (April 2015) for Tivoli Storage Productivity Center (withdrawn)
Refresh Pack 5.2.6 (June 2015) for Tivoli Storage Productivity Center
Refresh Pack 5.2.7 (August 2015) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.9 (October 2015) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.8 (December 2015)
IBM Spectrum Control V5.2.9 (February 2016)
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
Fix Pack 5.1.1.12 (October 2016) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.13 (February 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.14 (June 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.15 (Sept 2017) for Tivoli Storage Productivity Center
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
Fix Pack 5.1.1.8 (July 2015) for Tivoli Storage Productivity Center
Fix Pack 5.2.7.1 (February 2016) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
Zoning operations issued against Brocade Network Advisor (BNA) through Storage Control experience timeouts resulting in failed zoning tasks. The timeout happens when TPC/eTPC takes longer to complete than the Storage Control zoning timeout allows. Storage Control uses TPC via API so the TPC side of this is fairly Evidence of this problem from a TPC perspective is shown when a "rollbackTransaction" is logged in the zoning job logs: 2013-09-19 10:32:07.584+08:00 INFO Entry com.ibm.tpc.fabric.FabricManagerService rollbackTransaction WebContainer : 0 2013-09-19 10:20:51.116+08:00 INFO Entry com.ibm.tpc.fabric.FabricManagerService commitTransaction WebContainer : 2 2013-09-19 10:32:07.595+08:00 ERROR com.ibm.tpc.control.interfaces.JobInProgressException at com.ibm.tpc.control.ControlEngine.checkToken(ControlEngine.java: 1585) at com.ibm.tpc.control.ControlEngine.startJob(ControlEngine.java:20 8) at com.ibm.tpc.control.ControlRouter.invoke(ControlRouter.java:180) at $Proxy9.rollbackTransaction(Unknown Source) at com.ibm.tpc.fabric.FabricManagerService.rollbackTransaction(Fabr icManagerService.java:5508) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessor Impl.java:79) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethod AccessorImpl.java:43) at java.lang.reflect.Method.invoke(Method.java:618) at org.apache.soap.server.RPCRouter.invoke(RPCRouter.java:146) at org.apache.soap.providers.RPCJavaProvider.invoke(RPCJavaProvider .java:129) At this point, no commands were sent to BNA during the commit, so no zoning actions are taken resulting in the timeout failure in Storage Control. RECREATE STEPS: Perform zoning operations against Brocade fabrics via Storage Control, observe timeout ________________________________________________________________ DB2 Version used for Server: N/A The defect is against component: 5608TPCD1 TPC Device Manager Server/Manager build/release (TPC): 4.2.2.143 Agent build/release (TPC): N/A Server/Manager (OS): N/A Agent (OS): N/A ________________________________________________________________ Problem as described by customer: Brocade zoning failure/eTPC with Director Initial customer impact (low/med/high): High
Local fix
Contact support for fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Systems Director users deploying VMs using TPC 5.2.0, * * 5.1.1.x or earlier. * **************************************************************** * PROBLEM DESCRIPTION: * * VM deployment may fail due to a zoning rollback error. * **************************************************************** * RECOMMENDATION: * * Upgrade to fixing maintenance when available. In the * * meantime, you can increase the timeout value within IBM * * Systems Director. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | fix pack | 5.1.1-TIV-TPC-FP0005 - target July 2014 | refresh pack | 5.2-TIV-TPC-RP0001 - target March 2014 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs or fix packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IC97375
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-11-01
Closed date
2013-12-26
Last modified date
2014-07-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FABRIC
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
R511 PSY
UP
R520 PSY
UP
Document Information
Modified date: