IC96805: INCORRECT COEFFICIENTS WHEN TIMESERIES TOOLKIT OPERATORS ARIMA, LPC AND DSPFILTER GET MULTIPLE MONITOR CONTROL SIGNALS

 

APAR status

  • Closed as fixed if next.

Error description

  • Timeseries Toolkit operators such as ARIMA, LPC, VAR, and
    DSPFilter support the use of an optional input control port.
    The "monitor" control signal will submit the coefficients to
    the optional monitor output port for later use. If multiple
    monitor control signals are passed to an operator, however, the
    operator returns the old coefficients. This problem occurs
    because the old coefficients are not cleared before a new set
    of coefficients are read from the model.
    

Local fix

  • There is no work-around for this defect.
    

Problem summary

  • Users Affected: Users who develop applications that use monitor
    control signals with operators LPC, ARIMA and DSPFilter in the
    Timeseries Toolkit.
    
    Problem Description: See Error Description.
    
    Problem Conclusion: This problem is fixed in Version 3.1 Fix
    Pack 1 and later fix packs.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IC96805

  • Reported component name

    INFOSPHERE STRE

  • Reported component ID

    5724Y95IS

  • Reported release

    310

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-10

  • Closed date

    2013-10-29

  • Last modified date

    2013-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R310 PSY

       UP

Rate this page: