IC93286: PCOM: MOUBTN KEYWORD ON DDS WINDOW FAILS ON SOME SCREENS

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Personal Communications v6.0.6/v6.0.7
    
    The program has 2 DDS-WINDOW.
    In 1st WINDOW, the function key is effective when pushing the
    mouse button, but the 2nd WIDNOW, the function key is not
    effective when pushing the mouse button.
    
    OIA shows X ?+ with the message that Response Time Monitor
    (RTM) key is pressed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All 5250 emulation users configured with     *
    *                 Mouse Button keyword (MOUBTN)                *
    ****************************************************************
    * PROBLEM DESCRIPTION: In Personal Communications 5250 display *
    *                      session, existing Programmable Mouse    *
    *                      Buttons (PMB) configuration is not      *
    *                      cleared when a new PMB configuration    *
    *                      is received.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    5250 emulator display session has a PMB structured field
    where left mouse event AID key is mapped to a key, for
    example "F4". When a new PMB structured field without left
    mouse event AID is received, the existing PMB structured
    field is not cleared. This may result in incorrect behavior
    on the new emulator screen.
    

Problem conclusion

  • PCSLT52.DLL and PCSPREF.DLL have been changed to add a new
    keyword ClearPMB to the 5250 section of the WS profile. When
    this keyword is set to Y, the existing PMB structured field
    will be cleared when a new PMB structured field is received.
    By default, the keyword is set to N.
    
    To add the new keyword, use a ASCII editor to open the WS
    profile:
    
    [5250]
    ClearPMB=Y
    
    Fix is scheduled for PCOM 6.0.9 Refresh Pack
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC93286

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I7000

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-21

  • Closed date

    2013-08-20

  • Last modified date

    2013-08-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • PCSLT52  PCSPREF
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R601 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Personal Communications

Software version:

6.0.1

Reference #:

IC93286

Modified date:

2013-08-20

Translate my page