IBM Support

IC92537: ERROR 1-6-2002 OCCURS WHEN TRANSLATING INBOUND FILE THAT GENERATES OUTBOUND ACKNOWLEDGEMENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Gentran crashes and these errors are in Audit Log:-
    1-6-2001 Error Translation using gntxeng.exe failed with error
    80040702 and 80010105.
    1-6-2002 Warning Translation using gntxeng.exe failed with
    error 80040702 and 80010105. RPC_E_SERVERFAULT detected.
    Commpost module is entering retry logic. Retry attempt number
    is 5 of 5.
    

Local fix

  • STRRTC 374003
    JDH/JDH
    Circumvention:
    No workaround is possible
    A codefix is required, expected to be included in 5.3.1 (Patch
    2)
    

Problem summary

  • User Affected: Customers running GSW 5.3.1
    Inbound file processing with acknowledgment generation causes
    error in txackgen.dll and crashes Gentran.
    

Problem conclusion

  • TxAckGen.dll would fail if the ack type was NULL in the ack
    generation process.  As part of a previous fix for AK5 / IK5
    error reporting in 999s & 997s,
    we check our ack type for specific error reporting.  If our ack
    type is NULL, this check fails.  Added code to skip this check
    if our ack type is null since it's only
    needed for 997s & 999s.
    Delivered in:
    GSW 5.3.1.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC92537

  • Reported component name

    STR GENTRAN MS

  • Reported component ID

    5725D0903

  • Reported release

    531

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-23

  • Closed date

    2013-07-31

  • Last modified date

    2013-07-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    STR GENTRAN MS

  • Fixed component ID

    5725D0903

Applicable component levels

  • R531 PSY

       UP

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SS6V3G","label":"Sterling Gentran:Server for Microsoft Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"531","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
31 July 2013