IC92525: DATE/TIME DISPLAY IN AUDIT LOG IS CORRUPT WHEN REGIONAL AND LANGUAGE SETTINGS ARE GERMAN, BUT THE LOCAL IS ENGLISH

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The problem with the time display occurs when the time string
    does not match the settings for the System Local.  For example,
    if the Regional and Language Settings are German but the Local
    is English.  The Windows OLE library defaults the Local ID to
    the Local of the User.  However, the value of the string in the
    result set is different, because of the Regional Setting.  This
    mismatch, system configuration versus current user causes the
    date format function to fail, which causes the date field to
    contain garbage.
    

Local fix

  • STRRTC  378075
    STRRTC  377817
    AE/AE
    Set the regional and language settings to English
    

Problem summary

  • User Affected:
    Customers with User Account Date Time setting formats that
    differ from those in the Windows settings for the Region.
    
    Problem Description:
    The Audit Log Date/Time column could display corrupted dates.
    This would occur if the Regional Settings in the Contol
    Panel differred from the Regional Setting of the DB server and
    the Date Time Format of the DB was not the same as the
    system running GSW.
    

Problem conclusion

  • Resolution Summary:
    If the attempt to format the date/time fails, as described
    above, display the date/time string provided by the DB
    without formating or adjusting for the current locale or user
    format preferences.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC92525

  • Reported component name

    STR GENTRAN MS

  • Reported component ID

    5725D0903

  • Reported release

    531

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-23

  • Closed date

    2013-06-11

  • Last modified date

    2013-06-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR GENTRAN MS

  • Fixed component ID

    5725D0903

Applicable component levels

  • R531 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Sterling Gentran:Server for Microsoft Windows

Software version:

531

Reference #:

IC92525

Modified date:

2013-06-11

Translate my page

Machine Translation

Content navigation