Error description

  • Sterling Gentran Server for Microsoft Windows
    All versions
    
    When Release in the EDI Associations area of the Map Editor is
    set to a number higher than the small int max of 32767 or less
    than 0, you will not be able to assign the compiled object
    (TPL) to any partner relationship.
    

Local fix

  • STRRTC 371770
    WW/WW
    
    Circumvention:
    Workaround is to change the value in the Release box to a
    number between 0 and 32767
    

Problem summary

  • Users Affected:
    Customers running GSW 5.1, 5.2, 5.3, & 5.3.1
    
    Map Release Version getting set to negative number in DB if no
    association is entered in map Details dialog
    

Problem conclusion

  • Resolution Summary:
    
    Set EDI Associations Release Versions in Details window to a
    default value of zero.  Changed the Edi Associations Release
    field to a numeric only field and added validation checking to
    ensure that the integer value is between 0 & 32767. Added two
    new warning messages for the validation check of the Edi
    Associations Release value to inform the user of which value is
    out of range.
    
    Delivered In:
    5.1.0.54
    5.2.0.24
    5.3.0.6
    5.3.1.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC91493

  • Reported component name

    STR GENTRAN MS

  • Reported component ID

    5725D0903

  • Reported release

    531

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-11

  • Closed date

    2013-06-14

  • Last modified date

    2013-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR GENTRAN MS

  • Fixed component ID

    5725D0903

Applicable component levels

  • R510 PSY

       UP

  • R520 PSY

       UP

  • R530 PSY

       UP

  • R531 PSY

       UP

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SS6V3G","label":"Sterling Gentran:Server for Microsoft Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"531","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 June 2013