IC90902: NODE INFORMATION IS MISSING FROM EXISTING NODE WHEN VIEWING FROM THE CONSOLE AND THEY STAYS IN ? STATUS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • There is no validation for invalid characters is done by the
    Simple SLC Wizard,  if Control Center is running on a UNIX
    system, the user could create a simple SLC with an asterisk in
    it, and while Windows rejects it, UNIX accepts it, and writes
    the SLC to the disk, while no rule gets created. When the
    engine tries to start up, it throws exceptions that the cache
    for a given DVG could not be created, and the start up process
    is skewed.
    

Local fix

  • STRRTC - 370542
    SF / SF
    Circumvention: None
    

Problem summary

  • Description of issue: Node information for an existing node is
    missing when viewed from the console.
    

Problem conclusion

  • Description of fix: Added validation logic to Simple SLC group
    creation, as it would create rules with invalid IDs which would
    further mess up the node service start up.
    

Temporary fix

  • Description of issue: Node information for an existing node is
    missing when viewed from the console.
    
    Description of fix: Added validation logic to Simple SLC group
    creation, as it would create rules with invalid IDs which would
    further mess up the node service start up.
    

Comments

APAR Information

  • APAR number

    IC90902

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-15

  • Closed date

    2013-03-25

  • Last modified date

    2013-03-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

  • R540 PSY

       UP