Error description

  • When a cluster disk is parted into 2 or more partitions, only
    the first partition drive letter is correctly obtained and
    random values return for the successive partitions.
    
    The returned random values may cause FastBack client to
    erroneously report owning of a cluster disk for the passive
    node. Snapshots would fail with time out error for volumes on
    this cluster disk, and log could be found in FastBack Server:
     AGI_SendMonitorCtrlInternal: command sent to 2 agent(s)
    

Local fix

  • n/a
    

Problem summary

  • *
    ****************************************************************
    * USERS AFFECTED: IBM Tivoli Storage Manager FastBack client   *
    *                 versions 6.1.6, 6.1.7 running on all Microsoft
    *                 Windows platforms.                           *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: When a cluster disk is parted into 2    *
    *                      or more partitions, only the first      *
    *                      partition drive letter is correctly     *
    *                      obtained and random values may return   *
    *                      for the successive partitions.          *
    *                      The returned random values may cause    *
    *                      FastBack client to erroneously report   *
    *                      owning of a cluster disk for the        *
    *                      passive node. Snapshots would fail      *
    *                      with time out error for volumes on      *
    *                      this cluster disk, and log could be     *
    *                      found in FastBack Server:               *
    *                      AGI_SendMonitorCtrlInternal: command    *
    *                      sent to 2 agent(s)                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    * Apply fixing level when available. This problem is currently *
    * projected to be fixed in fix pack 6.1.9. Note that until the *
    * fixing level is available, this information is subject to    *
    * change at the discretion of IBM.                             *
    ****************************************************************
     *
    ****************************************************************
    *
    

Problem conclusion

  • IBM Tivoli Storage Manager FastBack Client is fixed to correctly
    report partition information for clustered disk parted into
    multiple partitions.
    

Temporary fix

  • A fix for this problem is currently targeted for interim fix
    package 6.1.8.1. Until the interim fix is actually available
    this information is subject to change at the discretion of IBM
    

Comments

APAR Information

  • APAR number

    IC90817

  • Reported component name

    TSM FASTBACK

  • Reported component ID

    5724FSBBK

  • Reported release

    61W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-13

  • Closed date

    2013-04-17

  • Last modified date

    2013-08-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM FASTBACK

  • Fixed component ID

    5724FSBBK

Applicable component levels

  • R61W PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli Storage Manager FastBack

Software version:

6.1

Reference #:

IC90817

Modified date:

2013-08-22

Translate my page

Machine Translation

Content navigation