IC90701: SCHEDULED REPORTS FROM STERLING CONTROL CENTER WILL NOT RUN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • CGNS004E Failed to e-mail the specified report"
    and/or ERROR ScheduledReportsJob - Unable to generate report
    output. Exception Msg :java.lang.NullPointerException
    

Local fix

  • STRRTC - 369534
    SF/ SF
    Circumvention: None
    

Problem summary

  • Description of issue: Automated reports do not work due to a
    bug that was introduced in 5.4.0.1 release.
    

Problem conclusion

  • Description of fix: Fixed the code to check if the report is
    being executed by the engine, as is the case for an automated
    report
    

Temporary fix

  • Will provide a fix.
    

Comments

APAR Information

  • APAR number

    IC90701

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-07

  • Closed date

    2013-03-15

  • Last modified date

    2013-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels