IC90332: GENTRAN SERVER FOR MICROSOFT WINDOWS BUILD MAP FOR 997 DOES NOT MEET STANDARDS

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Gentran Server for Microsoft Windows All Releases
    
    The AK1 segment of the 997 was updates in 004041 to include a
    3rd element.
    

Local fix

  • STRRTC 364201
    WW/WW
    
    The AK1 03 (0480) can be copied into the existing BLD997.MAP
    for a newly created 997 map with a version of 004041 or higher.
    
    The Edit > Details of the map should be changed so the
    installed version of the map is not overwritten on
    compile/registration. The file name should be changed as well.
    

Problem summary

  • Users Affected:
    Customers running GSW 5.1, 5.2, 5.3, & 5.3.1
    
    BLD997.MAP does not have the AK103 element (0480) to populate
    the GS08 version
    

Problem conclusion

  • Resolution Summary:
    
    BLD997 map was missing the AK103 segment which is an option
    segment that was added in standard version 004041.
    This was added to the BLD997.map which can be found in the
    support folder of the patch install under:
         Maps > Special > Source > BLD997_AK103.map.
    
    The tpl file can be found in the support folder under:
         Maps > Special > Compiled > BLD997_AK103.tpl.
    
    
    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    !!!!!!
    NOTE: THESE SYSTEM MAPS WILL NOT BE INSTALLED BY THE PATCH
    INSTALL.
    YOU MUST GO THE SUPPORT FOLDER AND REGISTER THE TPL FILES
    MANUALLY
    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    !!!!!!
    
    Delivered In:
    5.1.0.53
    5.2.0.23
    5.3.0.5
    5.3.1.0
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC90332

  • Reported component name

    STR GENTRAN MS

  • Reported component ID

    5725D0903

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-20

  • Closed date

    2013-02-20

  • Last modified date

    2013-02-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR GENTRAN MS

  • Fixed component ID

    5725D0903

Applicable component levels

  • R510 PSY

       UP

  • R520 PSY

       UP

  • R530 PSY

       UP

  • R531 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Sterling Gentran:Server for Microsoft Windows

Software version:

5.1

Reference #:

IC90332

Modified date:

2013-02-20

Translate my page

Machine Translation

Content navigation