IC90207: HAC PARAMETER ERE.REQUIREDPINGFAILURES IS INEFFECTIVE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When using the External Reference Entity (ERE) functionality
    with solidDB HotStandby and solidDB High Availability Controller
    (HAC), the ERE.RequiredPingFailures parameter setting is
    ineffective.
    
    The ERE.RequiredPingFailures in the HAC configuration file
    (solidhac.ini) defines the maximum number of consecutive ping
    calls that must fail before the HAC concludes that the server is
    disconnected from the ERE and isolated from the client network.
    
    However, setting the ERE.RequiredPingFailures parameter has no
    effect. Instead, the number of pings is controlled by the
    HAController.RequiredConnectFailures parameter.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All HAC users using ERE.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to V7.0 Fix Pack 5.                                  *
    ****************************************************************
    

Problem conclusion

  • Fix is include in V7.0 Fix Pack 5. The ERE.RequiredPingFailures
    parameter now works as documented.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC90207

  • Reported component name

    SOLIDDB-DB2/IDS

  • Reported component ID

    5724V1700

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-14

  • Closed date

    2013-03-01

  • Last modified date

    2013-03-01

  • APAR is sysrouted FROM one or more of the following:

    IC89799

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SOLIDDB-DB2/IDS

  • Fixed component ID

    5724V1700

Applicable component levels

  • R650 PSY

       UP

  • R700 PSY

       UP



Rate this page: