IC90087: LOGS FILLED WITH NET.SF.SAXON.TRANS.DYNAMICERROR: AMBIGUOUS RULE MATCH

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • The Sterling Control Center logs are filled with the INFO
    messages, net.sf.saxon.trans.DynamicError: Ambiguous rule match
    

Local fix

  • STRRTC - 365541
    SF / SF
    Circumvention: None
    

Problem summary

  • Description of issue:  Numerous "Ambiguous rule match for
    /event" errors were filling up the engine log.  In this case the
    customer defined a large number of rules.  When the compiled
    rules require more than 64K, a particular rules parser (saxon)
    is invoked.  SCC erroneously omitted the insertion of a priority
    value in each rule, which ensures uniqueness, causing the error
    message.
    

Problem conclusion

  • Description of fix:   Added logic to generate a unique priority
    number for each rule, when using saxon to compile the rules.
    

Temporary fix

  • Added logic to generate a unique priority number for each rule,
    when using the saxon to compile the rules.
    

Comments

APAR Information

  • APAR number

    IC90087

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    52X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-07

  • Closed date

    2013-03-15

  • Last modified date

    2013-03-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

  • R52X PSY

       UP

  • R530 PSY

       UP

  • R540 PSY

       UP