A fix is available
APAR status
Closed as program error.
Error description
It is legal SPL code to have an Import operator with an output stream that that is not input by any operators. If you submit the SPL application as a job, Streams Studio reports a NullPointerException when it refreshes the information about the instance. Additionally, when you attempt to view the application with the "Show Application Graph" command in Streams Studio, a NullPointerException occurs.
Local fix
To work around the problem, add an operator that takes the Import output stream as input. This operator can be just a temporary placeholder, for example, a Custom operator that does nothing with the input. Alternatively, remove the Import operator from the SPL source code.
Problem summary
Users Affected: Developers who are using Streams Studio with an application that has an Import operator with no stream connections to any downstream operators.
Problem conclusion
Problem Conclusion: This problem is fixed in Version 3.0 Fix Pack 1 and later fix packs.
Temporary fix
Comments
APAR Information
APAR number
IC89755
Reported component name
INFOSPHERE STRE
Reported component ID
5724Y95IS
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-22
Closed date
2013-02-01
Last modified date
2013-02-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFOSPHERE STRE
Fixed component ID
5724Y95IS
Applicable component levels
R300 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.